Skip to main content
Home > Pump skid for industrial and process chillers
Process

Pump skidfor industrial and process chillers

It takes the water from the chiller unit and delivers it to the process at the temperature required, stable within ±0.5 °C. Buffer tank, two pumps, mixing valve and control panel in a single module, ready to connect.

~10 m³/hdesign flow rate
(~50 kW at ΔT 5 K)
±0.5 °Csupply temperature accuracy
Templari hydronic skid for process chillers

Designed for

Processes that cannot stop

Process cooling is not about air-conditioning a room: it cools a machine or a production line, and product quality and production continuity depend on a stable temperature.

Plastics moulding

Laser and machine tools

Electroplating

Food and beverage

Pharmaceutical

Technical rooms and data rooms

Benefits

The process sets the operating point, not the machine

The buffer tank and the mixing valve deliver the temperature the process needs, regardless of the fluctuations of the chiller unit.

±0.5 °C

You choose the temperature

Supply temperature adjustable from 10 to 50 °C. The three-way mixing valve keeps it stable at the set value.

2 pumps

If one pump stops, production does not

Two IE5 electronic pumps at constant differential pressure. If one stops, the other keeps the line running.

400 L

Stainless steel tank

Stainless steel buffer tank with four connections and an anti-stratification baffle.

1 module

Ready to connect

Tank, pumps, valve, filter, safety devices and electrical panel come pre-assembled: just connect the DN50 headers and the power supply.

Data sheet

Skid technical specifications

Hydraulics
Fluid
water or water with 40% glycol
Design flow rate
~10 m³/h
Sizing
~50 kW at ΔT 5 K, also suitable for ΔT 3 K
Main headers
DN50 (2")
Tank and pumps
Buffer tank
400 L stainless steel, 4 connections, anti-stratification baffle
Pumps
2 IE5 electronic pumps, constant Δp
Bypass
differential
Expansion vessel
12 L
Safety valve
6 bar
Filling
automatic
Control
Controlled supply temperature
10 / 50 °C
Accuracy
±0.5 °C
Control
3-way mixing valve
Power supply
power and control panel, 400 V · 3 ph · 50 Hz

Pairing

It pairs with Templari R290 air-to-water heat pumps

The chiller unit produces the water, the skid stores it and delivers it to the process at the set temperature. A new, more powerful version is coming, in production from January 2027.

Sizing

We tell you which size you need

Flow rate, temperature difference and the temperature required by the process: with these three figures one of our technicians checks the pairing.

FAQ

Frequently asked questions

The answers you need before requesting a quote.

What temperature reaches the process?

The one you set, from 10 to 50 °C, with an accuracy of ±0.5 °C. It is controlled by the mixing valve of the skid.

What capacity is it sized for?

For about 50 kW with a temperature difference of 5 K, that is about 10 m³/h. It is also suitable for a difference of 3 K.

What happens if a pump fails?

The skid has two IE5 electronic pumps, not one: if one stops, the other keeps the line running.

Can glycol water be used?

Yes: the skid is designed for water or water with 40% glycol.

Which machine does it pair with?

With Templari air-to-water heat pumps using the natural refrigerant R290. One of our technicians checks the pairing against the process data.

Request a quote

Tell us about your process: a Templari technician will get back to you within 24 hours.

Prefer to talk now? Call us on+39 049 8597400

    By sending the request you accept the Privacy Policy.