{"id":25483,"date":"2026-11-01T11:47:56","date_gmt":"2026-11-01T10:47:56","guid":{"rendered":"https:\/\/templari.com\/electric-warehouse-heating\/"},"modified":"2026-11-01T11:47:56","modified_gmt":"2026-11-01T10:47:56","slug":"electric-warehouse-heating","status":"publish","type":"post","link":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/","title":{"rendered":"Electric warehouse heating: heaters, infrared, fan heaters, unit heaters or a heat pump, the real cost per kWh"},"content":{"rendered":"<div id=\"aa\">\n<style>body:has(#aa){overflow:visible!important;overflow-x:clip!important}body:has(#aa) .featured-media-under-header{display:none!important}body:has(#aa) .container-wrap{padding:0!important;background:#000!important}body:has(#aa) .container-wrap .main-content,body:has(#aa) .main-content>.row,body:has(#aa) .post-area,body:has(#aa) article.post,body:has(#aa) article .inner-wrap,body:has(#aa) .post-content,body:has(#aa) .content-inner{max-width:none!important;width:100%!important;padding:0!important;margin:0!important;float:none!important}body:has(#aa) .comments-section{display:none}#aa{background:#000;color:#E9E8DD;font-family:Poppins,Arial,sans-serif;font-size:19px;line-height:1.7;-webkit-font-smoothing:antialiased}#aa *{box-sizing:border-box}#aa .hero{position:relative;min-height:58vh;display:flex;align-items:flex-end;background:#000 center\/cover no-repeat}#aa .hero:before{content:\"\";position:absolute;inset:0;background:linear-gradient(90deg,rgba(0,0,0,.9) 0%,rgba(0,0,0,.6) 55%,rgba(0,0,0,.2) 100%),linear-gradient(0deg,#000 0%,rgba(0,0,0,0) 45%)}#aa .hero .in{position:relative;max-width:1160px;margin:0 auto;padding:120px 24px 44px;width:100%}#aa .badge{display:inline-block;font-size:13px;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#0BABE4;border:1px solid rgba(11,171,228,.5);border-radius:999px;padding:6px 16px;margin-bottom:18px;background:rgba(0,0,0,.35);-webkit-backdrop-filter:blur(8px);backdrop-filter:blur(8px)}#aa h1{font-size:clamp(32px,4.4vw,52px);line-height:1.15;font-weight:700;color:#fff!important;margin:0 0 18px;max-width:20ch}#aa .lead{font-size:20px;color:#E9E8DD!important;max-width:62ch;margin:0}#aa .subnav{position:sticky;top:76px;z-index:20;display:flex;justify-content:center;padding:14px 12px;background:transparent;pointer-events:none}#aa .subnav nav{pointer-events:auto;display:flex;gap:6px;overflow-x:auto;max-width:100%;padding:6px;border-radius:999px;background:rgba(20,20,20,.72);border:1px solid rgba(255,255,255,.14);-webkit-backdrop-filter:blur(14px);backdrop-filter:blur(14px);scrollbar-width:none}#aa .subnav a{white-space:nowrap;font-size:14px;font-weight:600;color:#E9E8DD!important;text-decoration:none!important;padding:8px 16px;border-radius:999px}#aa .subnav a.on,#aa .subnav a:hover{background:#0BABE4;color:#051822!important}#aa .sec{padding:52px 0;scroll-margin-top:150px}#aa .wrap{max-width:820px;margin:0 auto;padding:0 24px}#aa .num{font-size:13px;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#0BABE4;margin:0 0 6px}#aa h2{font-size:clamp(28px,3.2vw,38px);line-height:1.2;font-weight:700;color:#fff!important;margin:0 0 18px}#aa p,#aa li{color:#E9E8DD!important;font-size:19px}#aa p{margin:0 0 18px}#aa a{color:#45E3FF!important;text-decoration:underline;text-underline-offset:3px}#aa ul,#aa ol{margin:0 0 18px;padding:0;list-style:none}#aa li{position:relative;padding-left:28px;margin:0 0 10px}#aa ul li:before{content:\"\";position:absolute;left:4px;top:.72em;width:9px;height:9px;border-radius:50%;background:#0BABE4}#aa figure{margin:30px 0}#aa figure img{display:block;width:auto;max-width:100%;max-height:600px;height:auto;margin:0 auto;border-radius:22px;box-shadow:0 22px 48px rgba(0,0,0,.45)}#aa figcaption{font-size:15px!important;line-height:1.5;color:#B9C6CC!important;margin-top:12px;text-align:left}#aa .chiara{background:#F5F4EE;color:#051822}#aa .chiara h2{color:#051822!important}#aa .chiara .num{color:#05587a}#aa .chiara p,#aa .chiara li{color:#1d2b33!important}#aa .chiara a{color:#05587a!important}#aa .chiara ul li:before{background:#05587a}#aa .chiara figure img{box-shadow:0 20px 44px rgba(5,24,34,.20)}#aa .chiara figcaption{color:#3C4F5A!important}#aa .chiara strong,#aa .chiara b{color:#051822}#aa table{width:100%;border-collapse:collapse;margin:0 0 20px;font-size:16px}#aa th,#aa td{padding:10px 12px;border-bottom:1px solid rgba(255,255,255,.14);text-align:left;color:inherit!important;background:transparent!important}#aa .chiara th,#aa .chiara td{border-color:rgba(5,24,34,.14)}#aa .faq .wrap{max-width:1160px;display:grid;grid-template-columns:minmax(0,1fr) minmax(0,2fr);gap:40px}#aa details{border-bottom:1px solid rgba(255,255,255,.16);padding:18px 0}#aa .chiara details{border-color:rgba(5,24,34,.16)}#aa summary{list-style:none;cursor:pointer;font-size:19px;font-weight:600;color:#fff;display:flex;justify-content:space-between;gap:18px}#aa .chiara summary{color:#051822}#aa summary::-webkit-details-marker{display:none}#aa summary:after{content:\"+\";color:#0BABE4;font-size:26px;line-height:1;font-weight:400}#aa .chiara summary:after{color:#05587a}#aa details[open] summary:after{content:\"\\2212\"}#aa details p{margin:12px 0 0}#aa .larga,#aa .fine .wrap{max-width:1160px}@media(min-width:1000px){#aa .duo .larga{display:grid;grid-template-columns:minmax(0,1.1fr) minmax(0,1fr);gap:56px;align-items:start}#aa .duo.inv .testo{order:2}#aa .duo .foto{position:sticky;top:190px}#aa .duo .foto figure{margin:0 0 26px}#aa .duo .foto figure:last-child{margin-bottom:0}#aa .duo .foto img{max-height:72vh}#aa .duo.senza .larga{grid-template-columns:minmax(0,1fr) minmax(0,1.6fr)}#aa .duo.senza .testa{position:sticky;top:190px}}body:has(#aa) #header-outer{background:#000!important}#aa .fine{padding:36px 0 52px}#aa .fine p{font-size:16px}@media(max-width:820px){#aa{font-size:18px}#aa p,#aa li{font-size:18px}#aa .hero{min-height:auto}#aa .hero .in{padding:96px 20px 32px}#aa .lead{font-size:18px}#aa .sec{padding:40px 0}#aa .wrap{padding:0 20px}#aa .subnav{top:64px}#aa .faq .wrap{grid-template-columns:1fr;gap:8px}}<\/style>\n<section class=\"hero\" style=\"background-image:url(https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg)\">\n<div class=\"in\"><span class=\"badge\">Technical tips<\/span><\/p>\n<h1>Electric warehouse heating: heaters, infrared, fan heaters, unit heaters or a heat pump, the real cost per kWh<\/h1>\n<p class=\"lead\">\u201cElectric heating\u201d for a warehouse means four different kinds of warehouse heaters: an industrial resistance heater, an infrared panel, an electric hot-air generator, or a hot-water unit heater fed by something that heats the water. They cost little to buy and a lot to run, apart from one. Here we line up the four systems and the air-to-air heat pump with the same yardstick: how many kilowatt-hours of electricity it takes for every kilowatt-hour of heat in the warehouse, and what that means at the end of winter.<\/p>\n<\/div>\n<\/section>\n<div class=\"subnav\">\n<nav><a href=\"#s1\">The yardstick that matters: kWh of heat per kWh of electricity<\/a><a href=\"#s2\">Electric warehouse heaters and industrial fan heaters<\/a><a href=\"#s3\">Infrared<\/a><a href=\"#s4\">Electric hot-air generators<\/a><a href=\"#s5\">Hot-water unit heaters<\/a><a href=\"#s6\">Air-to-air heat pump for warehouses<\/a><a href=\"#s7\">The cost per kWh and per season, an example with stated assumptions<\/a><a href=\"#s8\">When electric heating still makes sense<\/a><a href=\"#s9\">Incentives and contracted power<\/a><a href=\"#s10\">Frequently asked questions<\/a><\/nav>\n<\/div>\n<section id=\"s1\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">01<\/p>\n<h2>The yardstick that matters: kWh of heat per kWh of electricity<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>A resistance heater turns 1 kWh of electricity into 1 kWh of heat, always. It cannot do more: that is the physical limit of Joule heating. A heat pump takes heat from the outside air and carries it inside: with 1 kWh of electricity it delivers 3, 4 or 5, depending on the outdoor temperature. The ratio is called COP, and in our <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-cop-scop-eer\/\" rel=\"noreferrer\">article on COP<\/a> we explained how to read it. The whole comparison on this page rests on that number: 1 against 3-5.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s2\" class=\"sec duo senza chiara\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">02<\/p>\n<h2>Electric warehouse heaters and industrial fan heaters<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>The industrial resistance fan heater, from 3 to 30 kW, costs a few hundred euros and plugs into a three-phase socket. It heats the air where it stands, and hot air rises under the warehouse roof, where nobody needs it. Three limits: the COP is 1; it needs an enormous contracted electrical power, because a 400 m\u00b2 warehouse asks for 20-40 kW of heat, which with resistances means 20-40 kW of electricity; and stratification forces it to heat the ceiling first. It is the right solution for an emergency or for a small room used for a few hours.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s3\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">03<\/p>\n<h2>Infrared<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>Infrared panels and lamps do not heat the air but the surfaces and people they radiate on. For fixed workstations in an otherwise cold warehouse they work: whoever stands under them feels warm even with the air at 10 \u00b0C. The COP stays 1, and the warmth ends when you leave the cone. They do not heat the warehouse: they heat the people, as long as they stand still underneath. For a whole space they cost as much as resistance heaters.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s4\" class=\"sec duo senza chiara\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">04<\/p>\n<h2>Electric hot-air generators<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>These are bigger resistance heaters, from 20 to 100 kW, with ducts or outlets, often used as temporary site heating. Same COP of 1, same contracted power, plus the noise of the big fan. They make sense where there is nothing else and only for a short time.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s5\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">05<\/p>\n<h2>Hot-water unit heaters<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>The hot-water unit heater is a terminal: a finned coil with a fan, hung on a wall or ceiling, with hot water flowing through it. Something else has to make the water: a gas or oil boiler, or an air-to-water heat pump. On its own it consumes almost nothing; the generator is what consumes. With a gas boiler you pay for the gas and you have two systems, hydronic and air handling, with pipes running through the whole warehouse. With an air-to-water heat pump the COP is there, but the water has to be brought to 45-50 \u00b0C to make the unit heaters perform, and part of the advantage is lost. It is the typical solution of warehouses built twenty years ago.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s6\" class=\"sec duo chiara inv\">\n<div class=\"wrap larga\">\n<div class=\"testo\">\n<p class=\"num\">06<\/p>\n<h2>Air-to-air heat pump for warehouses<\/h2>\n<p>The <a href=\"https:\/\/templari.com\/en\/air-to-air-heat-pumps-34-48-kw\/\" rel=\"noreferrer\">Kita Air<\/a> takes heat from the outside air and delivers it straight into the warehouse air, without water, without pipes, without a boiler. It has a seasonal COP of up to 5.15 as declared in the datasheet, and it heats in winter and cools in summer with the same machine. One machine covers 400-500 m\u00b2; large warehouses are done with several machines, from 300 to 30,000 m\u00b2. The limit compared with the heater is the purchase price, much higher, and the installation, which has to be done by an installer. The advantage is all in the consumption.<\/p>\n<\/div>\n<div class=\"foto\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-magazzini.jpg\" alt=\"Kita Air air-to-air heat pump installed in a warehouse: the warm air goes straight into the space, with no water or pipes\" width=\"1200\" height=\"800\" loading=\"lazy\" \/><figcaption>Kita Air in a warehouse: heat taken from the outside air goes directly into the warehouse air.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s7\" class=\"sec duo\">\n<div class=\"wrap larga\">\n<div class=\"testo\">\n<p class=\"num\">07<\/p>\n<h2>The cost per kWh and per season, an example with stated assumptions<\/h2>\n<p>Assumptions: electricity at \u20ac0.25\/kWh, gas at \u20ac1.10\/m\u00b3 with 10 kWh per m\u00b3 and a boiler at 90%, air-to-air heat pump with a seasonal average COP of 3.5, cautious compared with the nameplate 5.15, a 400 m\u00b2 warehouse that needs 40,000 kWh of heat in a season.<\/p>\n<ul>\n<li>Resistance heaters, infrared, electric generators: 40,000 kWh of electricity, \u20ac10,000.<\/li>\n<li>Hot-water unit heaters with gas boiler: 4,440 m\u00b3 of gas, \u20ac4,900, plus the boiler and the pipes.<\/li>\n<li>Air-to-air heat pump: 11,400 kWh of electricity, \u20ac2,860.<\/li>\n<\/ul>\n<p>Change the assumptions and the numbers change, not the order: resistance heating costs three and a half times as much as the heat pump, every winter. Whoever has <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-and-photovoltaics\/\" rel=\"noreferrer\">photovoltaics on the roof<\/a> of the warehouse lowers the third number even further, because the heat pump works in the daytime.<\/p>\n<\/div>\n<div class=\"foto\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-capannoni.jpg\" alt=\"Kita Air air-to-air heat pumps in an industrial warehouse: one machine every 400-500 square metres\" width=\"1200\" height=\"800\" loading=\"lazy\" \/><figcaption>One machine every 400-500 m\u00b2: large warehouses are done with several Kita Air units, up to 30,000 m\u00b2.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s8\" class=\"sec duo senza chiara\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">08<\/p>\n<h2>When electric heating still makes sense<\/h2>\n<\/div>\n<div class=\"testo\">\n<ul>\n<li>Small room, used a few hours a week: the heater costs little and the consumption weighs little.<\/li>\n<li>Fixed workstation in a warehouse you do not want to heat entirely: infrared over the workstation.<\/li>\n<li>Emergency or building site: hot-air generator for hire.<\/li>\n<\/ul>\n<p>In all other cases, a warehouse used eight hours a day, resistance electric heating is the most expensive system there is.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s9\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">09<\/p>\n<h2>Incentives and contracted power<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>The Italian incentive, the Conto Termico, covers the heat pump for businesses, not resistance heaters: the details are on the <a href=\"https:\/\/templari.com\/en\/heat-pump-grants-tax-relief-uk\/\" rel=\"noreferrer\">incentives page<\/a>. On electrical power: 40 kW of resistance heaters ask for 40 kW contracted, while a Kita Air of 40 kW thermal draws about 10. Often the difference decides on its own, because raising the meter&#8217;s power costs money and is sometimes not available. How many kW your warehouse needs is explained in the <a href=\"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/\" rel=\"noreferrer\">calculation guide<\/a>; for a quote <a href=\"https:\/\/templari.com\/en\/contacts\/\" rel=\"noreferrer\">write to us<\/a> with the square metres and the height.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s10\" class=\"sec faq chiara\">\n<div class=\"wrap\">\n<div>\n<p class=\"num\">10<\/p>\n<h2>Frequently asked questions<\/h2>\n<\/div>\n<div>\n<details>\n<summary>How much does an industrial electric heater consume?<\/summary>\n<p>As much as its power rating: a 15 kW unit consumes 15 kWh for every hour of operation, because the resistance turns all the electricity into heat and no more.<\/p>\n<\/details>\n<details>\n<summary>Is infrared worth it for a warehouse?<\/summary>\n<p>It is worth it for warming people at a fixed workstation, not the warehouse. The consumption per kWh of heat is the same as a resistance heater.<\/p>\n<\/details>\n<details>\n<summary>Is the hot-water unit heater electric?<\/summary>\n<p>No: it is a terminal that needs hot water produced by a boiler or an air-to-water heat pump. On its own it only consumes the fan.<\/p>\n<\/details>\n<details>\n<summary>How much do you save with a heat pump compared with resistance heaters?<\/summary>\n<p>With a seasonal COP of 3.5 you need less than a third of the electricity: in this page&#8217;s example \u20ac2,860 against \u20ac10,000 per season for a 400 m\u00b2 warehouse.<\/p>\n<\/details>\n<details>\n<summary>How many kW does it take to heat a warehouse?<\/summary>\n<p>It depends on volume and insulation: the dedicated guide has the method, with the rule of thumb and the real calculation.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"fine\">\n<div class=\"wrap\">\n<p class=\"tpl-vedi-anche\"><strong>See also:<\/strong> <a href=\"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/\" rel=\"noreferrer\">How many kW it takes to heat a warehouse<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-cop-scop-eer\/\" rel=\"noreferrer\">Heat pump COP<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-and-photovoltaics\/\" rel=\"noreferrer\">Heat pump and photovoltaics<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/air-to-air-heat-pumps-34-48-kw\/\" rel=\"noreferrer\">Heating industrial warehouses<\/a><\/p>\n<p><em>All the heating expert&#8217;s tips are on the <a href=\"https:\/\/templari.com\/en\/technical-tips\/\" rel=\"noreferrer\">column page<\/a>.<\/em><\/p>\n<\/div>\n<\/section>\n<\/div>\n<p><script>(function(){var a=[].slice.call(document.querySelectorAll('#aa .subnav a')),n=document.querySelector('#aa .subnav'),h=document.getElementById('header-outer');function u(){if(n&&h)n.style.top=Math.max(0,h.getBoundingClientRect().bottom)+'px';var y=window.scrollY+200,c=null;a.forEach(function(l){var s=document.querySelector(l.getAttribute('href'));if(s&&s.offsetTop<=y)c=l});a.forEach(function(l){l.classList.toggle('on',l===c)});if(c)if(c!==u.c){u.c=c;c.parentNode.scrollTo({left:c.offsetLeft-20,behavior:'smooth'})}}window.addEventListener('scroll',function(){u();setTimeout(u,400)},{passive:true});u()})();<\/script><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How much does an industrial electric heater consume?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"As much as its power rating: a 15 kW unit consumes 15 kWh for every hour of operation, because the resistance turns all the electricity into heat and no more.\"}}, {\"@type\": \"Question\", \"name\": \"Is infrared worth it for a warehouse?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is worth it for warming people at a fixed workstation, not the warehouse. The consumption per kWh of heat is the same as a resistance heater.\"}}, {\"@type\": \"Question\", \"name\": \"Is the hot-water unit heater electric?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No: it is a terminal that needs hot water produced by a boiler or an air-to-water heat pump. On its own it only consumes the fan.\"}}, {\"@type\": \"Question\", \"name\": \"How much do you save with a heat pump compared with resistance heaters?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"With a seasonal COP of 3.5 you need less than a third of the electricity: in this page's example \\u20ac2,860 against \\u20ac10,000 per season for a 400 m\\u00b2 warehouse.\"}}, {\"@type\": \"Question\", \"name\": \"How many kW does it take to heat a warehouse?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It depends on volume and insulation: the dedicated guide has the method, with the rule of thumb and the real calculation.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Technical tips Electric warehouse heating: heaters, infrared, fan heaters, unit heaters or a heat pump, the real cost per kWh \u201cElectric heating\u201d for a warehouse means four different kinds of&#8230;<\/p>\n","protected":false},"author":3,"featured_media":11183,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_meta-robots-noindex":"","footnotes":""},"categories":[201],"tags":[],"class_list":["post-25483","post","type-post","status-publish","format-standard","has-post-thumbnail","category-technical-tips"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Warehouse heating systems: electric, infrared or heat pump<\/title>\n<meta name=\"description\" content=\"Industrial heaters, infrared, electric fan heaters and hot water unit heaters compared with an air-to-air heat pump: the cost per kWh and per season.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Warehouse heating systems: electric, infrared or heat pump\" \/>\n<meta property=\"og:description\" content=\"Industrial heaters, infrared, electric fan heaters and hot water unit heaters compared with an air-to-air heat pump: the cost per kWh and per season.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/\" \/>\n<meta property=\"og:site_name\" content=\"Templari\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-01T10:47:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Templari Admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Templari Admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Warehouse heating systems: electric, infrared or heat pump","description":"Industrial heaters, infrared, electric fan heaters and hot water unit heaters compared with an air-to-air heat pump: the cost per kWh and per season.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/","og_locale":"en_US","og_type":"article","og_title":"Warehouse heating systems: electric, infrared or heat pump","og_description":"Industrial heaters, infrared, electric fan heaters and hot water unit heaters compared with an air-to-air heat pump: the cost per kWh and per season.","og_url":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/","og_site_name":"Templari","article_published_time":"2026-11-01T10:47:56+00:00","og_image":[{"width":1200,"height":800,"url":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg","type":"image\/jpeg"}],"author":"Templari Admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Templari Admin","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#article","isPartOf":{"@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/"},"author":{"name":"Templari Admin","@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794"},"headline":"Electric warehouse heating: heaters, infrared, fan heaters, unit heaters or a heat pump, the real cost per kWh","datePublished":"2026-11-01T10:47:56+00:00","mainEntityOfPage":{"@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/"},"wordCount":1255,"image":{"@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#primaryimage"},"thumbnailUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg","articleSection":["Technical tips"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/","url":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/","name":"Warehouse heating systems: electric, infrared or heat pump","isPartOf":{"@id":"https:\/\/templari.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#primaryimage"},"image":{"@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#primaryimage"},"thumbnailUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg","datePublished":"2026-11-01T10:47:56+00:00","author":{"@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794"},"description":"Industrial heaters, infrared, electric fan heaters and hot water unit heaters compared with an air-to-air heat pump: the cost per kWh and per season.","breadcrumb":{"@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#primaryimage","url":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg","contentUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/KITA-AIR-PREMIUM-aree-produttive-officine.jpg","width":1200,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/templari.com\/en\/"},{"@type":"ListItem","position":2,"name":"Electric warehouse heating: heaters, infrared, fan heaters, unit heaters or a heat pump, the real cost per kWh"}]},{"@type":"Person","@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794","name":"Templari Admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","caption":"Templari Admin"}}]}},"_links":{"self":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/25483","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/comments?post=25483"}],"version-history":[{"count":0,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/25483\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/media\/11183"}],"wp:attachment":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/media?parent=25483"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/categories?post=25483"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/tags?post=25483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}