{"id":25475,"date":"2026-11-01T11:47:42","date_gmt":"2026-11-01T10:47:42","guid":{"rendered":"https:\/\/templari.com\/heat-pump-flow-temperature\/"},"modified":"2026-11-01T11:47:42","modified_gmt":"2026-11-01T10:47:42","slug":"heat-pump-flow-temperature","status":"publish","type":"post","link":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/","title":{"rendered":"Heat pump flow temperature: what underfloor heating, fan coils and radiators need, and who sets it"},"content":{"rendered":"<div id=\"aa\">\n<style>body:has(#aa){overflow:visible!important;overflow-x:clip!important}body:has(#aa) .featured-media-under-header{display:none!important}body:has(#aa) .container-wrap{padding:0!important;background:#000!important}body:has(#aa) .container-wrap .main-content,body:has(#aa) .main-content>.row,body:has(#aa) .post-area,body:has(#aa) article.post,body:has(#aa) article .inner-wrap,body:has(#aa) .post-content,body:has(#aa) .content-inner{max-width:none!important;width:100%!important;padding:0!important;margin:0!important;float:none!important}body:has(#aa) .comments-section{display:none}#aa{background:#000;color:#E9E8DD;font-family:Poppins,Arial,sans-serif;font-size:19px;line-height:1.7;-webkit-font-smoothing:antialiased}#aa *{box-sizing:border-box}#aa .hero{position:relative;min-height:58vh;display:flex;align-items:flex-end;background:#000 center\/cover no-repeat}#aa .hero:before{content:\"\";position:absolute;inset:0;background:linear-gradient(90deg,rgba(0,0,0,.9) 0%,rgba(0,0,0,.6) 55%,rgba(0,0,0,.2) 100%),linear-gradient(0deg,#000 0%,rgba(0,0,0,0) 45%)}#aa .hero .in{position:relative;max-width:1160px;margin:0 auto;padding:120px 24px 44px;width:100%}#aa .badge{display:inline-block;font-size:13px;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#0BABE4;border:1px solid rgba(11,171,228,.5);border-radius:999px;padding:6px 16px;margin-bottom:18px;background:rgba(0,0,0,.35);-webkit-backdrop-filter:blur(8px);backdrop-filter:blur(8px)}#aa h1{font-size:clamp(32px,4.4vw,52px);line-height:1.15;font-weight:700;color:#fff!important;margin:0 0 18px;max-width:20ch}#aa .lead{font-size:20px;color:#E9E8DD!important;max-width:62ch;margin:0}#aa .subnav{position:sticky;top:76px;z-index:20;display:flex;justify-content:center;padding:14px 12px;background:transparent;pointer-events:none}#aa .subnav nav{pointer-events:auto;display:flex;gap:6px;overflow-x:auto;max-width:100%;padding:6px;border-radius:999px;background:rgba(20,20,20,.72);border:1px solid rgba(255,255,255,.14);-webkit-backdrop-filter:blur(14px);backdrop-filter:blur(14px);scrollbar-width:none}#aa .subnav a{white-space:nowrap;font-size:14px;font-weight:600;color:#E9E8DD!important;text-decoration:none!important;padding:8px 16px;border-radius:999px}#aa .subnav a.on,#aa .subnav a:hover{background:#0BABE4;color:#051822!important}#aa .sec{padding:52px 0;scroll-margin-top:150px}#aa .wrap{max-width:820px;margin:0 auto;padding:0 24px}#aa .num{font-size:13px;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#0BABE4;margin:0 0 6px}#aa h2{font-size:clamp(28px,3.2vw,38px);line-height:1.2;font-weight:700;color:#fff!important;margin:0 0 18px}#aa p,#aa li{color:#E9E8DD!important;font-size:19px}#aa p{margin:0 0 18px}#aa a{color:#45E3FF!important;text-decoration:underline;text-underline-offset:3px}#aa ul,#aa ol{margin:0 0 18px;padding:0;list-style:none}#aa li{position:relative;padding-left:28px;margin:0 0 10px}#aa ul li:before{content:\"\";position:absolute;left:4px;top:.72em;width:9px;height:9px;border-radius:50%;background:#0BABE4}#aa figure{margin:30px 0}#aa figure img{display:block;width:auto;max-width:100%;max-height:600px;height:auto;margin:0 auto;border-radius:22px;box-shadow:0 22px 48px rgba(0,0,0,.45)}#aa figcaption{font-size:15px!important;line-height:1.5;color:#B9C6CC!important;margin-top:12px;text-align:left}#aa .chiara{background:#F5F4EE;color:#051822}#aa .chiara h2{color:#051822!important}#aa .chiara .num{color:#05587a}#aa .chiara p,#aa .chiara li{color:#1d2b33!important}#aa .chiara a{color:#05587a!important}#aa .chiara ul li:before{background:#05587a}#aa .chiara figure img{box-shadow:0 20px 44px rgba(5,24,34,.20)}#aa .chiara figcaption{color:#3C4F5A!important}#aa .chiara strong,#aa .chiara b{color:#051822}#aa table{width:100%;border-collapse:collapse;margin:0 0 20px;font-size:16px}#aa th,#aa td{padding:10px 12px;border-bottom:1px solid rgba(255,255,255,.14);text-align:left;color:inherit!important;background:transparent!important}#aa .chiara th,#aa .chiara td{border-color:rgba(5,24,34,.14)}#aa .faq .wrap{max-width:1160px;display:grid;grid-template-columns:minmax(0,1fr) minmax(0,2fr);gap:40px}#aa details{border-bottom:1px solid rgba(255,255,255,.16);padding:18px 0}#aa .chiara details{border-color:rgba(5,24,34,.16)}#aa summary{list-style:none;cursor:pointer;font-size:19px;font-weight:600;color:#fff;display:flex;justify-content:space-between;gap:18px}#aa .chiara summary{color:#051822}#aa summary::-webkit-details-marker{display:none}#aa summary:after{content:\"+\";color:#0BABE4;font-size:26px;line-height:1;font-weight:400}#aa .chiara summary:after{color:#05587a}#aa details[open] summary:after{content:\"\\2212\"}#aa details p{margin:12px 0 0}#aa .larga,#aa .fine .wrap{max-width:1160px}@media(min-width:1000px){#aa .duo .larga{display:grid;grid-template-columns:minmax(0,1.1fr) minmax(0,1fr);gap:56px;align-items:start}#aa .duo.inv .testo{order:2}#aa .duo .foto{position:sticky;top:190px}#aa .duo .foto figure{margin:0 0 26px}#aa .duo .foto figure:last-child{margin-bottom:0}#aa .duo .foto img{max-height:72vh}#aa .duo.senza .larga{grid-template-columns:minmax(0,1fr) minmax(0,1.6fr)}#aa .duo.senza .testa{position:sticky;top:190px}}body:has(#aa) #header-outer{background:#000!important}#aa .fine{padding:36px 0 52px}#aa .fine p{font-size:16px}@media(max-width:820px){#aa{font-size:18px}#aa p,#aa li{font-size:18px}#aa .hero{min-height:auto}#aa .hero .in{padding:96px 20px 32px}#aa .lead{font-size:18px}#aa .sec{padding:40px 0}#aa .wrap{padding:0 20px}#aa .subnav{top:64px}#aa .faq .wrap{grid-template-columns:1fr;gap:8px}}<\/style>\n<section class=\"hero\" style=\"background-image:url(https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp)\">\n<div class=\"in\"><span class=\"badge\">Technical tips<\/span><\/p>\n<h1>Heat pump flow temperature: what underfloor heating, fan coils and radiators need, and who sets it<\/h1>\n<p class=\"lead\">The heat pump flow temperature is the temperature of the water leaving the heat pump for the heating system. It is the number that, more than any other, decides how much a heat pump consumes: with the same house, the same cold outside and the same machine, sending water at 45 \u00b0C instead of 35 costs a quarter more electricity. Here we explain which flow temperature each type of system needs, why it is usually set higher than necessary, and how our machines find it by themselves, system by system, even on an old system.<\/p>\n<\/div>\n<\/section>\n<div class=\"subnav\">\n<nav><a href=\"#s1\">What is the heat pump flow temperature, and how it differs from the return<\/a><a href=\"#s2\">Which flow temperature each system needs<\/a><a href=\"#s3\">What each extra degree costs<\/a><a href=\"#s4\">Why the flow temperature is set higher than necessary<\/a><a href=\"#s5\">The limit of the heating curve<\/a><a href=\"#s6\">How HCC finds the lowest flow temperature, on any system<\/a><a href=\"#s7\">What changes on the bill<\/a><a href=\"#s8\">Old system: what to check<\/a><a href=\"#s9\">What to ask before buying<\/a><a href=\"#s10\">Frequently asked questions<\/a><\/nav>\n<\/div>\n<section id=\"s1\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">01<\/p>\n<h2>What is the heat pump flow temperature, and how it differs from the return<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>The flow is the hot water leaving the machine; the return is the same water coming back after giving up heat to the floor, fan coils or radiators. The difference between the two, generally 5-7 degrees with a heat pump, is the heat delivered to the house. On data sheets the flow temperature appears as &#8220;outlet water temperature&#8221;: it is the condition at which output and COP are measured, for example 35 \u00b0C for underfloor heating and 55 \u00b0C for radiators.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s2\" class=\"sec duo chiara inv\">\n<div class=\"wrap larga\">\n<div class=\"testo\">\n<p class=\"num\">02<\/p>\n<h2>Which flow temperature each system needs<\/h2>\n<p>Each emitter gives off heat in a different way and needs water at a different temperature.<\/p>\n<ul>\n<li>Underfloor heating: in a standard system the water runs at 28-35 \u00b0C, with the higher value on the coldest days. Our machines go lower: in a house with underfloor heating controlled by HCC the water sits at 23 \u00b0C in the morning and rises to 27-28 \u00b0C in the evening on the coldest days. The surface is large, barely warm water is enough, and this is where a heat pump performs best.<\/li>\n<li>Fan coils: 40-45 \u00b0C. A fan blows air over the coil, so the heat exchange surface is small but crossed by a lot of air. We wrote about it in the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-fan-coil\/\" rel=\"noreferrer\">tip on fan coils<\/a>.<\/li>\n<li>Radiators: it depends on how large they are compared with the room. A system designed for a boiler at 70 \u00b0C works, with a heat pump, between 45 and 55 \u00b0C on the coldest days, and much lower in the mid-seasons. See the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-with-radiators-does-it-work\/\" rel=\"noreferrer\">tip on radiators<\/a>.<\/li>\n<li>Domestic hot water: it is not a heating flow temperature, but the machine must reach 55-60 \u00b0C in the cylinder. Ours reach 70 \u00b0C when needed.<\/li>\n<\/ul>\n<p>These are the values for the coldest days. For most of the winter a system needs 5-10 degrees less, and that is where consumption is decided.<\/p>\n<\/div>\n<div class=\"foto\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/Componente-Sensore-ROOM-HD.webp\" alt=\"HCC ROOM sensor: it measures the temperature and humidity of the room and lets you change the temperature from the room itself\" width=\"828\" height=\"612\" loading=\"lazy\" \/><figcaption>The ROOM sensor: the flow temperature is decided on the temperature of the rooms, not on the outdoor one.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s3\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">03<\/p>\n<h2>What each extra degree costs<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>With a heat pump heat is not produced, it is moved: the higher the temperature it has to be brought to, the harder the compressor works. In the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-cop-scop-eer\/\" rel=\"noreferrer\">tip on COP<\/a> we showed the certified data of one of our machines: going from 35 to 55 \u00b0C of flow temperature costs about a third of the COP, at any outdoor temperature. Spread over the 20 degrees of difference, that is about 1.5-2% of consumption for every extra degree of flow temperature. Ten extra degrees, kept all winter to be safe, are 15-20% of the heating bill.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s4\" class=\"sec duo senza chiara\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">04<\/p>\n<h2>Why the flow temperature is set higher than necessary<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>Whoever commissions the system sets the flow temperature, or the heating curve that governs it, with the coldest day of the year in mind and a house full of cold people calling. To be safe, they add a margin: 5 degrees, sometimes 10. The margin stays all season, even on mild days, which are the majority. It is not the installer&#8217;s mistake: with a boiler that margin cost almost nothing, because a boiler&#8217;s efficiency changes little with water temperature. With a heat pump it is the most expensive item.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s5\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">05<\/p>\n<h2>The limit of the heating curve<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>Most heat pumps control the flow temperature with the heating curve: each outdoor temperature corresponds to a water temperature. It is a method that looks outside and not inside: it does not know whether the house is at 19 or 22 degrees, whether the sun is shining on the windows, whether the floor has already stored heat. We wrote about it in the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-heating-curve-weather-compensation\/\" rel=\"noreferrer\">tip on the heating curve<\/a>. The result is that the curve has to be adjusted by hand, and whoever adjusts it keeps it high.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s6\" class=\"sec duo chiara inv\">\n<div class=\"wrap larga\">\n<div class=\"testo\">\n<p class=\"num\">06<\/p>\n<h2>How HCC finds the lowest flow temperature, on any system<\/h2>\n<p>Templari heat pumps come with HCC as standard, the control system that reads the sensors in the rooms and runs the system. With HCC active nobody chooses the flow temperature in advance: the machine starts low and raises the water only as much as needed to keep the rooms at the requested temperature. If at 32 \u00b0C the rooms stay at 20, it stays at 32; if the house starts to cool down, it goes up. The system temperature entered on the panel, for example 45 \u00b0C, is the maximum that can be reached, not the target.<\/p>\n<p>This holds for whatever system is already in the house: underfloor heating, fan coils, large or small radiators, mixed systems with several zones. The machine does not need to know how the system is built: it measures it from the result. A system of oversized radiators finds by itself that 42 \u00b0C is enough; an underfloor system finds that 23-28 \u00b0C is enough, where a standard system sits at 28-35. The installer does not have to guess the right curve, and the safety margin no longer exists because the machine corrects course every time the house asks. The result, on the systems we follow, is a flow temperature on average 5 degrees lower than the same house would have with the heating curve: with the 1.5-2% per degree seen above, that is 7-10% less electricity for the whole winter, before even counting the hours when the machine runs much lower.<\/p>\n<p>With several zones HCC reasons zone by zone: the underfloor zone receives water mixed to its own temperature, the radiator zone the one it needs, and the machine produces only the highest of the current demands.<\/p>\n<\/div>\n<div class=\"foto\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/Schema-impianto-K-Touch-aria-acqua.webp\" alt=\"Diagram of an air-to-water system with HCC: heat pump, buffer tank, underfloor and radiator zones, sensors in the rooms and K-Touch panel\" width=\"1268\" height=\"1240\" loading=\"lazy\" \/><figcaption>A system with several zones: each zone receives water at its own temperature, and the machine produces only the highest of the current demands.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s7\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">07<\/p>\n<h2>What changes on the bill<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>In the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-energy-optimiser-thermal-storage\/\" rel=\"noreferrer\">tip on the energy optimiser<\/a> we described a house with underfloor heating where the flow temperature runs at 23 \u00b0C in the morning and at 27-28 \u00b0C in the evening, where an installer would have written a fixed 35 \u00b0C. The seasonal efficiency rises by one or two COP points, because the machine almost always works below the rated flow temperature value. With radiators the gain comes from time: more hours with low water, instead of a few hours with high water. The 65-70 \u00b0C our machines are capable of, described in the <a href=\"https:\/\/templari.com\/en\/news\/high-temperature-heat-pump\/\" rel=\"noreferrer\">tip on high temperature<\/a>, are rarely needed, and HCC uses them only when the house really asks for them.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s8\" class=\"sec duo senza chiara\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">08<\/p>\n<h2>Old system: what to check<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>Whoever puts a heat pump on an existing system is often told that &#8220;the radiators run at 70 degrees&#8221;. In most houses this is not so: the radiators were chosen generously, and the design day at -5 \u00b0C comes only a few days a year. Three checks before replacing the radiators: the <a href=\"https:\/\/templari.com\/en\/news\/how-to-balance-radiators-heat-pump\/\" rel=\"noreferrer\">hydraulic balancing<\/a>, because a radiator that receives little water calls for a high flow temperature for everyone; the thermostatic valves, which must let the water through when the flow temperature is low; and a winter test with the boiler lowered to 50 \u00b0C, which tells you straight away whether the house heats up anyway. The <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-old-house\/\" rel=\"noreferrer\">tip on the old house<\/a> has the complete path.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s9\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">09<\/p>\n<h2>What to ask before buying<\/h2>\n<\/div>\n<div class=\"testo\">\n<ul>\n<li>At what flow temperature the COP is declared: 35 \u00b0C is underfloor heating, 55 is radiators; the two numbers must be compared at the same flow temperature.<\/li>\n<li>Is the flow temperature fixed, does it follow a heating curve or does it adapt to the rooms? A fixed number is a margin paid all winter.<\/li>\n<li>How high the machine goes on the coldest days, without an electric heater.<\/li>\n<li>With several zones, whether each zone receives its own temperature or all receive the highest.<\/li>\n<\/ul>\n<p>If you are choosing a heat pump for a system that already exists, <a href=\"https:\/\/templari.com\/en\/contacts\/\" rel=\"noreferrer\">ask us for information<\/a>: we will tell you at what flow temperature it would work in your home.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s10\" class=\"sec faq chiara\">\n<div class=\"wrap\">\n<div>\n<p class=\"num\">10<\/p>\n<h2>Frequently asked questions<\/h2>\n<\/div>\n<div>\n<details>\n<summary>What is the right flow temperature for underfloor heating?<\/summary>\n<p>In a standard system 28-35 \u00b0C. With the room-based control of our machines the water stays between 23 and 28 \u00b0C for almost the whole winter: the floor is barely warm, and this is where the heat pump performs best.<\/p>\n<\/details>\n<details>\n<summary>What flow temperature do radiators need with a heat pump?<\/summary>\n<p>Between 45 and 55 \u00b0C on the coldest days if the system was designed for a boiler at 70 \u00b0C, and much less for the rest of the winter. With HCC active the machine finds the value that is enough by itself.<\/p>\n<\/details>\n<details>\n<summary>How much more do I consume for every degree of flow temperature?<\/summary>\n<p>About 1.5-2%: from the certified data of one of our machines, going from 35 to 55 \u00b0C costs about a third of the COP.<\/p>\n<\/details>\n<details>\n<summary>Can I set a fixed low flow temperature to save money?<\/summary>\n<p>On cold days the house does not heat up, and on mild days you waste just the same. Better a control that adapts to the rooms: it starts low and rises only when needed.<\/p>\n<\/details>\n<details>\n<summary>By how much does HCC lower the flow temperature?<\/summary>\n<p>On average by 5 degrees compared with the heating curve of the same house, that is 7-10% less electricity; on underfloor heating even more, because the water drops to 23-28 \u00b0C where a standard system sits at 28-35.<\/p>\n<\/details>\n<details>\n<summary>Do I need an installer to set the flow temperature on a Templari heat pump?<\/summary>\n<p>No: with HCC active the machine finds the flow temperature, on any system. On the panel you only enter the maximum the system can accept.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"fine\">\n<div class=\"wrap\">\n<p class=\"tpl-vedi-anche\"><strong>See also:<\/strong> <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-heating-curve-weather-compensation\/\" rel=\"noreferrer\">Heat pump heating curve<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-cop-scop-eer\/\" rel=\"noreferrer\">Heat pump COP<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-with-radiators-does-it-work\/\" rel=\"noreferrer\">Heat pump with radiators<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/high-temperature-heat-pump\/\" rel=\"noreferrer\">High-temperature heat pump<\/a><\/p>\n<p><em>All the technical tips are on the <a href=\"https:\/\/templari.com\/en\/technical-tips\/\" rel=\"noreferrer\">series page<\/a>.<\/em><\/p>\n<\/div>\n<\/section>\n<\/div>\n<p><script>(function(){var a=[].slice.call(document.querySelectorAll('#aa .subnav a')),n=document.querySelector('#aa .subnav'),h=document.getElementById('header-outer');function u(){if(n&&h)n.style.top=Math.max(0,h.getBoundingClientRect().bottom)+'px';var y=window.scrollY+200,c=null;a.forEach(function(l){var s=document.querySelector(l.getAttribute('href'));if(s&&s.offsetTop<=y)c=l});a.forEach(function(l){l.classList.toggle('on',l===c)});if(c)if(c!==u.c){u.c=c;c.parentNode.scrollTo({left:c.offsetLeft-20,behavior:'smooth'})}}window.addEventListener('scroll',function(){u();setTimeout(u,400)},{passive:true});u()})();<\/script><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the right flow temperature for underfloor heating?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In a standard system 28-35 \\u00b0C. With the room-based control of our machines the water stays between 23 and 28 \\u00b0C for almost the whole winter: the floor is barely warm, and this is where the heat pump performs best.\"}}, {\"@type\": \"Question\", \"name\": \"What flow temperature do radiators need with a heat pump?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Between 45 and 55 \\u00b0C on the coldest days if the system was designed for a boiler at 70 \\u00b0C, and much less for the rest of the winter. With HCC active the machine finds the value that is enough by itself.\"}}, {\"@type\": \"Question\", \"name\": \"How much more do I consume for every degree of flow temperature?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"About 1.5-2%: from the certified data of one of our machines, going from 35 to 55 \\u00b0C costs about a third of the COP.\"}}, {\"@type\": \"Question\", \"name\": \"Can I set a fixed low flow temperature to save money?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On cold days the house does not heat up, and on mild days you waste just the same. Better a control that adapts to the rooms: it starts low and rises only when needed.\"}}, {\"@type\": \"Question\", \"name\": \"By how much does HCC lower the flow temperature?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On average by 5 degrees compared with the heating curve of the same house, that is 7-10% less electricity; on underfloor heating even more, because the water drops to 23-28 \\u00b0C where a standard system sits at 28-35.\"}}, {\"@type\": \"Question\", \"name\": \"Do I need an installer to set the flow temperature on a Templari heat pump?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No: with HCC active the machine finds the flow temperature, on any system. On the panel you only enter the maximum the system can accept.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Technical tips Heat pump flow temperature: what underfloor heating, fan coils and radiators need, and who sets it The heat pump flow temperature is the temperature of the water leaving&#8230;<\/p>\n","protected":false},"author":3,"featured_media":11073,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_meta-robots-noindex":"","footnotes":""},"categories":[201],"tags":[],"class_list":["post-25475","post","type-post","status-publish","format-standard","has-post-thumbnail","category-technical-tips"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Heat pump flow temperature: underfloor heating and radiators<\/title>\n<meta name=\"description\" content=\"What flow temperature underfloor heating, fan coils and radiators need, what each extra degree costs and why with HCC the house sets it, not the installer.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Heat pump flow temperature: underfloor heating and radiators\" \/>\n<meta property=\"og:description\" content=\"What flow temperature underfloor heating, fan coils and radiators need, what each extra degree costs and why with HCC the house sets it, not the installer.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/\" \/>\n<meta property=\"og:site_name\" content=\"Templari\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-01T10:47:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1448\" \/>\n\t<meta property=\"og:image:height\" content=\"1086\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Templari Admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Templari Admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Heat pump flow temperature: underfloor heating and radiators","description":"What flow temperature underfloor heating, fan coils and radiators need, what each extra degree costs and why with HCC the house sets it, not the installer.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/","og_locale":"en_US","og_type":"article","og_title":"Heat pump flow temperature: underfloor heating and radiators","og_description":"What flow temperature underfloor heating, fan coils and radiators need, what each extra degree costs and why with HCC the house sets it, not the installer.","og_url":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/","og_site_name":"Templari","article_published_time":"2026-11-01T10:47:42+00:00","og_image":[{"width":1448,"height":1086,"url":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp","type":"image\/webp"}],"author":"Templari Admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Templari Admin","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#article","isPartOf":{"@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/"},"author":{"name":"Templari Admin","@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794"},"headline":"Heat pump flow temperature: what underfloor heating, fan coils and radiators need, and who sets it","datePublished":"2026-11-01T10:47:42+00:00","mainEntityOfPage":{"@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/"},"wordCount":1768,"image":{"@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#primaryimage"},"thumbnailUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp","articleSection":["Technical tips"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/","url":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/","name":"Heat pump flow temperature: underfloor heating and radiators","isPartOf":{"@id":"https:\/\/templari.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#primaryimage"},"image":{"@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#primaryimage"},"thumbnailUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp","datePublished":"2026-11-01T10:47:42+00:00","author":{"@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794"},"description":"What flow temperature underfloor heating, fan coils and radiators need, what each extra degree costs and why with HCC the house sets it, not the installer.","breadcrumb":{"@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#primaryimage","url":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp","contentUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/K-Touch-aria-acqua-casa.webp","width":1448,"height":1086},{"@type":"BreadcrumbList","@id":"https:\/\/templari.com\/en\/news\/heat-pump-flow-temperature\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/templari.com\/en\/"},{"@type":"ListItem","position":2,"name":"Heat pump flow temperature: what underfloor heating, fan coils and radiators need, and who sets it"}]},{"@type":"Person","@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794","name":"Templari Admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","caption":"Templari Admin"}}]}},"_links":{"self":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/25475","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/comments?post=25475"}],"version-history":[{"count":0,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/25475\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/media\/11073"}],"wp:attachment":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/media?parent=25475"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/categories?post=25475"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/tags?post=25475"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}