{"id":13233,"date":"2026-10-22T13:11:32","date_gmt":"2026-10-22T11:11:32","guid":{"rendered":"https:\/\/templari.com\/how-many-kw-to-heat-an-industrial-building\/"},"modified":"2026-11-06T09:40:08","modified_gmt":"2026-11-06T08:40:08","slug":"how-many-kw-to-heat-an-industrial-building","status":"publish","type":"post","link":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/","title":{"rendered":"Warehouse heating: how many kW to heat an industrial building and how it is calculated"},"content":{"rendered":"<div id=\"aa\">\n<style>body:has(#aa){overflow:visible!important;overflow-x:clip!important}body:has(#aa) .featured-media-under-header{display:none!important}body:has(#aa) .container-wrap{padding:0!important;background:#000!important}body:has(#aa) .container-wrap .main-content,body:has(#aa) .main-content>.row,body:has(#aa) .post-area,body:has(#aa) article.post,body:has(#aa) article .inner-wrap,body:has(#aa) .post-content,body:has(#aa) .content-inner{max-width:none!important;width:100%!important;padding:0!important;margin:0!important;float:none!important}body:has(#aa) .comments-section{display:none}#aa{background:#000;color:#E9E8DD;font-family:Poppins,Arial,sans-serif;font-size:19px;line-height:1.7;-webkit-font-smoothing:antialiased}#aa *{box-sizing:border-box}#aa .hero{position:relative;min-height:58vh;display:flex;align-items:flex-end;background:#000 center\/cover no-repeat}#aa .hero:before{content:\"\";position:absolute;inset:0;background:linear-gradient(90deg,rgba(0,0,0,.9) 0%,rgba(0,0,0,.6) 55%,rgba(0,0,0,.2) 100%),linear-gradient(0deg,#000 0%,rgba(0,0,0,0) 45%)}#aa .hero .in{position:relative;max-width:1160px;margin:0 auto;padding:120px 24px 44px;width:100%}#aa .badge{display:inline-block;font-size:13px;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#0BABE4;border:1px solid rgba(11,171,228,.5);border-radius:999px;padding:6px 16px;margin-bottom:18px;background:rgba(0,0,0,.35);-webkit-backdrop-filter:blur(8px);backdrop-filter:blur(8px)}#aa h1{font-size:clamp(32px,4.4vw,52px);line-height:1.15;font-weight:700;color:#fff!important;margin:0 0 18px;max-width:20ch}#aa .lead{font-size:20px;color:#E9E8DD!important;max-width:62ch;margin:0}#aa .subnav{position:sticky;top:76px;z-index:20;display:flex;justify-content:center;padding:14px 12px;background:transparent;pointer-events:none}#aa .subnav nav{pointer-events:auto;display:flex;gap:6px;overflow-x:auto;max-width:100%;padding:6px;border-radius:999px;background:rgba(20,20,20,.72);border:1px solid rgba(255,255,255,.14);-webkit-backdrop-filter:blur(14px);backdrop-filter:blur(14px);scrollbar-width:none}#aa .subnav a{white-space:nowrap;font-size:14px;font-weight:600;color:#E9E8DD!important;text-decoration:none!important;padding:8px 16px;border-radius:999px}#aa .subnav a.on,#aa .subnav a:hover{background:#0BABE4;color:#051822!important}#aa .sec{padding:52px 0;scroll-margin-top:150px}#aa .wrap{max-width:820px;margin:0 auto;padding:0 24px}#aa .num{font-size:13px;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#0BABE4;margin:0 0 6px}#aa h2{font-size:clamp(28px,3.2vw,38px);line-height:1.2;font-weight:700;color:#fff!important;margin:0 0 18px}#aa p,#aa li{color:#E9E8DD!important;font-size:19px}#aa p{margin:0 0 18px}#aa a{color:#45E3FF!important;text-decoration:underline;text-underline-offset:3px}#aa ul,#aa ol{margin:0 0 18px;padding:0;list-style:none}#aa li{position:relative;padding-left:28px;margin:0 0 10px}#aa ul li:before{content:\"\";position:absolute;left:4px;top:.72em;width:9px;height:9px;border-radius:50%;background:#0BABE4}#aa figure{margin:30px 0}#aa figure img{display:block;width:auto;max-width:100%;max-height:600px;height:auto;margin:0 auto;border-radius:22px;box-shadow:0 22px 48px rgba(0,0,0,.45)}#aa figcaption{font-size:15px!important;line-height:1.5;color:#B9C6CC!important;margin-top:12px;text-align:left}#aa .chiara{background:#F5F4EE;color:#051822}#aa .chiara h2{color:#051822!important}#aa .chiara .num{color:#05587a}#aa .chiara p,#aa .chiara li{color:#1d2b33!important}#aa .chiara a{color:#05587a!important}#aa .chiara ul li:before{background:#05587a}#aa .chiara figure img{box-shadow:0 20px 44px rgba(5,24,34,.20)}#aa .chiara figcaption{color:#3C4F5A!important}#aa .chiara strong,#aa .chiara b{color:#051822}#aa table{width:100%;border-collapse:collapse;margin:0 0 20px;font-size:16px}#aa th,#aa td{padding:10px 12px;border-bottom:1px solid rgba(255,255,255,.14);text-align:left;color:inherit!important;background:transparent!important}#aa .chiara th,#aa .chiara td{border-color:rgba(5,24,34,.14)}#aa .faq .wrap{max-width:1160px;display:grid;grid-template-columns:minmax(0,1fr) minmax(0,2fr);gap:40px}#aa details{border-bottom:1px solid rgba(255,255,255,.16);padding:18px 0}#aa .chiara details{border-color:rgba(5,24,34,.16)}#aa summary{list-style:none;cursor:pointer;font-size:19px;font-weight:600;color:#fff;display:flex;justify-content:space-between;gap:18px}#aa .chiara summary{color:#051822}#aa summary::-webkit-details-marker{display:none}#aa summary:after{content:\"+\";color:#0BABE4;font-size:26px;line-height:1;font-weight:400}#aa .chiara summary:after{color:#05587a}#aa details[open] summary:after{content:\"\\2212\"}#aa details p{margin:12px 0 0}#aa .larga,#aa .fine .wrap{max-width:1160px}@media(min-width:1000px){#aa .duo .larga{display:grid;grid-template-columns:minmax(0,1.1fr) minmax(0,1fr);gap:56px;align-items:start}#aa .duo.inv .testo{order:2}#aa .duo .foto{position:sticky;top:190px}#aa .duo .foto figure{margin:0 0 26px}#aa .duo .foto figure:last-child{margin-bottom:0}#aa .duo .foto img{max-height:72vh}#aa .duo.senza .larga{grid-template-columns:minmax(0,1fr) minmax(0,1.6fr)}#aa .duo.senza .testa{position:sticky;top:190px}}body:has(#aa) #header-outer{background:#000!important}#aa .fine{padding:36px 0 52px}#aa .fine p{font-size:16px}@media(max-width:820px){#aa{font-size:18px}#aa p,#aa li{font-size:18px}#aa .hero{min-height:auto}#aa .hero .in{padding:96px 20px 32px}#aa .lead{font-size:18px}#aa .sec{padding:40px 0}#aa .wrap{padding:0 20px}#aa .subnav{top:64px}#aa .faq .wrap{grid-template-columns:1fr;gap:8px}}<\/style>\n<section class=\"hero\" style=\"background-image:url(https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg)\">\n<div class=\"in\"><span class=\"badge\">Technical tips<\/span><\/p>\n<h1>Warehouse heating: how many kW to heat an industrial building and how it is calculated<\/h1>\n<p class=\"lead\">How many kW does a 400 square metre industrial building need? It is the question we hear most often, on Google and on the phone. The short answer is that one Kita Air is usually enough. The real answer depends on the building, and here we explain on what.<\/p>\n<\/div>\n<\/section>\n<div class=\"subnav\">\n<nav><a href=\"#s1\">Start from the volume, not the floor area<\/a><a href=\"#s2\">From 10 to 60 watts per cubic metre: it depends on how it is built<\/a><a href=\"#s3\">Open doors and air changes<\/a><a href=\"#s4\">The real number comes from the heat load calculation<\/a><a href=\"#s5\">The rule of thumb<\/a><a href=\"#s6\">Where the heat goes matters too<\/a><a href=\"#s7\">Neither too big nor too small<\/a><a href=\"#s8\">Frequently asked questions<\/a><\/nav>\n<\/div>\n<section id=\"s1\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">01<\/p>\n<h2>Start from the volume, not the floor area<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>Heat is calculated on the gross volume: external dimensions times height. A 400 m\u00b2 building 7 metres high holds 2,800 m\u00b3 of air, more than twice a house with the same floor plan. For a first estimate, the volume is multiplied by the watts each cubic metre loses on the coldest day of the area.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s2\" class=\"sec duo chiara inv\">\n<div class=\"wrap larga\">\n<div class=\"testo\">\n<p class=\"num\">02<\/p>\n<h2>From 10 to 60 watts per cubic metre: it depends on how it is built<\/h2>\n<p>It ranges from about 10 W\/m\u00b3 for a recent, insulated building to 40-60 W\/m\u00b3 and more for a prefabricated one with uninsulated roof and walls and doors that let air through. A poorly insulated building with leaky doors sits in between: 25 to 40. Two buildings with the same floor plan can need very different power.<\/p>\n<p>That is why on a site visit we look at:<\/p>\n<ul>\n<li>the height under the beams;<\/li>\n<li>the insulation of roof and walls;<\/li>\n<li>the doors: how many, how long they stay open, whether they leak;<\/li>\n<li>the skylights;<\/li>\n<li>the location, which sets the outdoor design temperature.<\/li>\n<\/ul>\n<\/div>\n<div class=\"foto\">\n<figure class=\"wp-block-image size-large\"><picture><source media=\"(max-width: 767px)\" srcset=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/capannone-potenza-wm3-en-telefono.jpg\" \/><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/capannone-potenza-wm3-en.jpg\" alt=\"Same 400 m\u00b2, different power: about 10 W\/m\u00b3 if the building is insulated, 25-40 W\/m\u00b3 and more if it is poorly insulated and the doors leak\" width=\"1672\" height=\"941\" \/><\/picture><figcaption>Same 400 m\u00b2, different power: about 10 W\/m\u00b3 if the building is insulated, 25-40 W\/m\u00b3 and more if it is poorly insulated and the doors leak.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s3\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">03<\/p>\n<h2>Open doors and air changes<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>The watts-per-cubic-metre figure holds with the doors closed. Every cubic metre of air that comes in from outside has to be heated from scratch: EN 12831 counts 0.34 W for every cubic metre per hour and every degree of difference. A building of 2,800 m\u00b3 with one complete air change per hour, 18 \u00b0C inside and -5 \u00b0C outside, loses about 22 kW this way: almost a whole Kita Air, just for the air coming in.<\/p>\n<p>In summer it is worse. With a door that stays open, warm humid air keeps coming in, and the machine spends its power removing the moisture (latent heat) instead of lowering the temperature: it dehumidifies, but it does not cool. It is like running the air conditioner at home with the windows wide open. For a 950 m\u00b2 building with a 4.5 \u00d7 4.5 m door open throughout production, we did not make an offer: no machine can guarantee 30 \u00b0C in those conditions.<\/p>\n<p>If the door has to stay open for the work, fix the door first: a high-speed door, an air curtain or an entrance lobby. Then size the machine.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s4\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">04<\/p>\n<h2>The real number comes from the heat load calculation<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>The real number is the heat loss calculation to EN 12831, made when a building is designed or refurbished: roof, walls, windows and doors, air changes. If it exists, the machine is chosen on the numbers. If it does not, or the building has changed, a site visit is needed.<\/p>\n<p>The calculation gives the power for the worst case, as EN 12831 requires: the coldest day, no sun, no machines running and no people. Free heat gains lower consumption over the year, not the power to be installed.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s5\" class=\"sec duo chiara inv\">\n<div class=\"wrap larga\">\n<div class=\"testo\">\n<p class=\"num\">05<\/p>\n<h2>The rule of thumb<\/h2>\n<p>From 150 to 500 m\u00b2 one Kita Air is usually enough, from 600 to 1,000 m\u00b2 two. Old buildings are usually kept cold: with one machine a poorly insulated building stays around 15 degrees, and those who have one often make do with it.<\/p>\n<\/div>\n<div class=\"foto\">\n<figure class=\"wp-block-image size-large\"><picture><source media=\"(max-width: 767px)\" srcset=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/capannone-termometri-en-telefono.jpg\" \/><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/capannone-termometri-en.jpg\" alt=\"Same Kita Air, 0 \u00b0C outside: 22 \u00b0C in the insulated building, 15 \u00b0C in the poorly insulated one\" width=\"1672\" height=\"941\" \/><\/picture><figcaption>Same Kita Air, 0 \u00b0C outside: 22 \u00b0C in the insulated building, 15 \u00b0C in the poorly insulated one.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s6\" class=\"sec duo senza\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">06<\/p>\n<h2>Where the heat goes matters too<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>In a building 7-8 metres high, warm air builds up under the roof, which is the largest surface and often the least insulated: the warmer it is up there, the more the roof loses. Bringing the heat back down to the floor, where people work, is not just comfort: it lowers the temperature under the roof and therefore the kW you need.<\/p>\n<p>In a tall building warm air rises under the roof and people working in the first two metres stay cold. That is why it is not only the kW that count, but where they go. The Kita Air split unit has a Venturi tube deflector as standard: it mixes the warm air with the air of the building and throws it out lukewarm, in much larger quantity, so it does not rise straight to the ceiling. In tall buildings the floor-standing unit draws air from below and sends it back with motorised louvres that form an air curtain: the heat stays on the floor, where it is needed. We covered this in the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-industrial-building-drawbacks-and-solutions\/\" rel=\"noreferrer\">article on the drawbacks of a heat pump in an industrial building<\/a>.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s7\" class=\"sec duo senza chiara\">\n<div class=\"wrap larga\">\n<div class=\"testa\">\n<p class=\"num\">07<\/p>\n<h2>Neither too big nor too small<\/h2>\n<\/div>\n<div class=\"testo\">\n<p>Fitting two machines where one is enough is not caution: a heat pump that is too big always runs at minimum and switches on and off all the time, as explained in the <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-inverter-sizing-half-capacity\/\" rel=\"noreferrer\">tip on sizing<\/a>.<\/p>\n<p>To know how many Kita Air units your building needs, the floor area, the height under the beams and the year of construction are enough. Write to us from the <a href=\"https:\/\/templari.com\/en\/air-to-air-heat-pumps-34-48-kw\/kita-air\/\" rel=\"noreferrer\">Kita Air page<\/a>.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"s8\" class=\"sec faq\">\n<div class=\"wrap\">\n<div>\n<p class=\"num\">08<\/p>\n<h2>Frequently asked questions<\/h2>\n<\/div>\n<div>\n<details>\n<summary>How many kW does a 400 m\u00b2 industrial building need?<\/summary>\n<p>One Kita Air is usually enough. The real figure is calculated on volume: a 400 m\u00b2 building 7 metres high has 2,800 m\u00b3, multiplied by the watts per cubic metre, from about 10 if it is insulated to 40-60 and more if it is not.<\/p>\n<\/details>\n<details>\n<summary>How many heat pumps does an industrial building need?<\/summary>\n<p>From 150 to 500 m\u00b2 one Kita Air is usually enough, from 600 to 1,000 m\u00b2 two. It depends on height, insulation, doors, skylights and climate zone.<\/p>\n<\/details>\n<details>\n<summary>What is checked during a site survey?<\/summary>\n<p>The clear height under the beams, roof and wall insulation, the doors (how many, how long they stay open, whether they leak), the skylights and the location, which sets the design outdoor temperature.<\/p>\n<\/details>\n<details>\n<summary>The door stays open during work: is a heat pump still worth it?<\/summary>\n<p>In winter it heats, but part of the power goes out with the incoming air: one complete air change per hour in 2,800 m\u00b3 at -5 \u00b0C costs about 22 kW. In summer, with the door open, no machine holds the temperature: it only removes moisture. Fix the door first, then the machine.<\/p>\n<\/details>\n<details>\n<summary>How do you stop the heat staying under the roof?<\/summary>\n<p>By distributing the air. The Kita Air split unit has a Venturi tube deflector as standard that mixes the warm air with the air in the building; in tall buildings the floor-standing unit sends out an air curtain that keeps the heat at ground level.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"fine chiara\">\n<div class=\"wrap\">\n<p class=\"tpl-vedi-anche\"><strong>See also:<\/strong> <a href=\"https:\/\/templari.com\/en\/news\/how-much-electricity-does-a-heat-pump-use\/\" rel=\"noreferrer\">How much electricity does a heat pump use: per day, per year and by size, with the data sheet figures<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/heat-pump-and-photovoltaics\/\" rel=\"noreferrer\">Heat pump and solar panels: how much the roof really covers, month by month, and how to make them work together<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/air-to-air-heat-pump\/\" rel=\"noreferrer\">Air to air heat pump: how it works, pros and cons, and when it makes sense for heating<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/workshop-heating\/\" rel=\"noreferrer\">Workshop heating: diesel heaters, infrared or a heat pump<\/a> \u00b7 <a href=\"https:\/\/templari.com\/en\/news\/electric-warehouse-heating\/\" rel=\"noreferrer\">Electric warehouse heating: heaters, infrared, fan heaters, unit heaters or a heat pump, the real cost per kWh<\/a><\/p>\n<p><em>All the technical tips are on the <a href=\"https:\/\/templari.com\/en\/technical-tips\/\" rel=\"noreferrer\">series page<\/a>. The next one in two weeks.<\/em><\/p>\n<\/div>\n<\/section>\n<\/div>\n<p><script>(function(){var a=[].slice.call(document.querySelectorAll('#aa .subnav a')),n=document.querySelector('#aa .subnav'),h=document.getElementById('header-outer');function u(){if(n&&h)n.style.top=Math.max(0,h.getBoundingClientRect().bottom)+'px';var y=window.scrollY+200,c=null;a.forEach(function(l){var s=document.querySelector(l.getAttribute('href'));if(s&&s.offsetTop<=y)c=l});a.forEach(function(l){l.classList.toggle('on',l===c)});if(c)if(c!==u.c){u.c=c;c.parentNode.scrollTo({left:c.offsetLeft-20,behavior:'smooth'})}}window.addEventListener('scroll',function(){u();setTimeout(u,400)},{passive:true});u()})();<\/script><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How many kW does a 400 m\\u00b2 industrial building need?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"One Kita Air is usually enough. The real figure is calculated on volume: a 400 m\\u00b2 building 7 metres high has 2,800 m\\u00b3, multiplied by the watts per cubic metre, from about 10 if it is insulated to 40-60 and more if it is not.\"}}, {\"@type\": \"Question\", \"name\": \"How many heat pumps does an industrial building need?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"From 150 to 500 m\\u00b2 one Kita Air is usually enough, from 600 to 1,000 m\\u00b2 two. It depends on height, insulation, doors, skylights and climate zone.\"}}, {\"@type\": \"Question\", \"name\": \"What is checked during a site survey?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The clear height under the beams, roof and wall insulation, the doors (how many, how long they stay open, whether they leak), the skylights and the location, which sets the design outdoor temperature.\"}}, {\"@type\": \"Question\", \"name\": \"The door stays open during work: is a heat pump still worth it?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In winter it heats, but part of the power goes out with the incoming air: one complete air change per hour in 2,800 m\\u00b3 at -5 \\u00b0C costs about 22 kW. In summer, with the door open, no machine holds the temperature: it only removes moisture. Fix the door first, then the machine.\"}}, {\"@type\": \"Question\", \"name\": \"How do you stop the heat staying under the roof?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"By distributing the air. The Kita Air split unit has a Venturi tube deflector as standard that mixes the warm air with the air in the building; in tall buildings the floor-standing unit sends out an air curtain that keeps the heat at ground level.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Technical tips Warehouse heating: how many kW to heat an industrial building and how it is calculated How many kW does a 400 square metre industrial building need? It is&#8230;<\/p>\n","protected":false},"author":3,"featured_media":13245,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_meta-robots-noindex":"","footnotes":""},"categories":[201],"tags":[],"class_list":["post-13233","post","type-post","status-publish","format-standard","has-post-thumbnail","category-technical-tips"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Warehouse heating: how many kW you need | Templari<\/title>\n<meta name=\"description\" content=\"Warehouse heating: how many kW for a 400 m\u00b2 building? Start from the volume, about 10 W\/m\u00b3 if insulated, 25-40 if not. Rule of thumb and real calculation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Warehouse heating: how many kW you need | Templari\" \/>\n<meta property=\"og:description\" content=\"Warehouse heating: how many kW for a 400 m\u00b2 building? Start from the volume, about 10 W\/m\u00b3 if insulated, 25-40 if not. Rule of thumb and real calculation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/\" \/>\n<meta property=\"og:site_name\" content=\"Templari\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-22T11:11:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-06T08:40:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"669\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Templari Admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Templari Admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Warehouse heating: how many kW you need | Templari","description":"Warehouse heating: how many kW for a 400 m\u00b2 building? Start from the volume, about 10 W\/m\u00b3 if insulated, 25-40 if not. Rule of thumb and real calculation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/","og_locale":"en_US","og_type":"article","og_title":"Warehouse heating: how many kW you need | Templari","og_description":"Warehouse heating: how many kW for a 400 m\u00b2 building? Start from the volume, about 10 W\/m\u00b3 if insulated, 25-40 if not. Rule of thumb and real calculation.","og_url":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/","og_site_name":"Templari","article_published_time":"2026-10-22T11:11:32+00:00","article_modified_time":"2026-11-06T08:40:08+00:00","og_image":[{"width":1672,"height":669,"url":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg","type":"image\/jpeg"}],"author":"Templari Admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Templari Admin","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#article","isPartOf":{"@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/"},"author":{"name":"Templari Admin","@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794"},"headline":"Warehouse heating: how many kW to heat an industrial building and how it is calculated","datePublished":"2026-10-22T11:11:32+00:00","dateModified":"2026-11-06T08:40:08+00:00","mainEntityOfPage":{"@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/"},"wordCount":1283,"image":{"@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#primaryimage"},"thumbnailUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg","articleSection":["Technical tips"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/","url":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/","name":"Warehouse heating: how many kW you need | Templari","isPartOf":{"@id":"https:\/\/templari.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#primaryimage"},"image":{"@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#primaryimage"},"thumbnailUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg","datePublished":"2026-10-22T11:11:32+00:00","dateModified":"2026-11-06T08:40:08+00:00","author":{"@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794"},"description":"Warehouse heating: how many kW for a 400 m\u00b2 building? Start from the volume, about 10 W\/m\u00b3 if insulated, 25-40 if not. Rule of thumb and real calculation.","breadcrumb":{"@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#primaryimage","url":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg","contentUrl":"https:\/\/templari.com\/wp-content\/uploads\/2026\/10\/p10-kita-air-capannone-produzione-2-5.jpg","width":1672,"height":669,"caption":"Kita Air indoor units in a production building"},{"@type":"BreadcrumbList","@id":"https:\/\/templari.com\/en\/news\/how-many-kw-to-heat-an-industrial-building\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/templari.com\/en\/"},{"@type":"ListItem","position":2,"name":"Warehouse heating: how many kW to heat an industrial building and how it is calculated"}]},{"@type":"Person","@id":"https:\/\/templari.com\/en\/#\/schema\/person\/f46afa3ae95aaf6f9bc6a0c7d6362794","name":"Templari Admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9f5f0005755bddc0e66d18c21bde62cb7ac725c3e4a3cb7dcbdf3c1cfce63f21?s=96&d=mm&r=g","caption":"Templari Admin"}}]}},"_links":{"self":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/13233","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/comments?post=13233"}],"version-history":[{"count":1,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/13233\/revisions"}],"predecessor-version":[{"id":14149,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/posts\/13233\/revisions\/14149"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/media\/13245"}],"wp:attachment":[{"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/media?parent=13233"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/categories?post=13233"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/templari.com\/en\/wp-json\/wp\/v2\/tags?post=13233"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}